A NEW! kind of DISPOSAL SYSTEM ~ 25 GPM ![]() ALTERNATIVE DRAINFIELD ![]() SIMPLY AMAZING! OPERATION The system control panel is equipped with four float switches and controls the timed doses to be discharged. The water level must be high enough to overcome the "Redundant Off" (Bottom) float in order for the pump to run. When the water level rises high enough to overcome the "Dose Enable" (second) float and the timer is in a dose enable mode, the cycle will initiate and activate the pump automatically backflush the disc filters, and dose the lead zone. The pump will continue to run for the length of time as set on the pump run timer to provide a complete dose. The system will remain off until the preprogrammed off timer enters a new cycle enable mode, at which time the control will activate another cycle and dose the new lead zone (as long as the "Dose Enable" float is still up). This process will continue until the water level drops below the "Dose Enable" float and the pump run timer has timed out. Each zone will automatically receive a field flush each 25 cycles to clean the drip tubing. The control system is equipped with a peak enable circuit to manage peak flows and excess water use event. If the water level rises enough to overcome the "peak enable" (third) float and the peak enable selector switch is on, the system will be cycled at the peak rate. The system will continue to cycle at an increased rate until the peak enable float is deactivated at which time the system will resume the normal dosing cycle. In the event the water level continues to rise enough to overcome the "High Level" (fourth) float, the audio/visual alarm will be activated until silenced by pressing the Test-Normal-Silence switch to the silence position. The alarm circuit must be reset when the "High Level" float returns to its normal position
|