Lift & Distance Table Instructions

Pressure Compensating (15 GPM)

  1. The vertical lift is the elevation difference between the “off float” and the highest point in any zone.
  2. The diameter of the pipe from the pump tank to the hydraulic unit is 1 ½” minimum.
  3. All supply and return pipes are 1″.
  4. The flush return pipe from the hydraulic unit to the pretreatment tank is 1 ½” gravity.
  5. The maximum distance from the pump tank to the hydraulic unit is 30′.
  6. The tables may be used with the standard zone detail configuration only. A calculation sheet must be filled out for any other configuration.
  7. Top feed manifolds must be used when any discernible slope is encountered.

Maximum Static Lift (“Off Level Float” to Drip Field)

Supply/Return Line (feet)2-Lat
300′
3-Lat
300′
4-Lat
300′
5-Lat
240′
6-Lat
165′
7-Lat
100′
100988875747977
150968469667068
200948163586159
250927757515249
300907350434440
350887044353531
400866638272621
4508463321917 
50082592612  
550805520   
600785214   
65076488   
70074452   
7507241    
8007037    
8506834    
9006630    
9506427    
10006223    